Testing of the admitance principle of the fault indicator
Musil, Milan ; Vyčítal, Václav (referee) ; Topolánek, David (advisor)
The thesis deals with the proposal, implementation and evaluation of test for fault condition indicators. Thesis focusing on earth fault indicators based on admittance principles. These indicators must be able to evaluate earth faults in compensated, compensated with auxiliary resistor, unearthed and high-resistance earthed networks. The proposed tests verify the current and voltage measurement errors in inputs including monitored characteristic variables such as conductance and susceptance. The proposed test are applied to a selected ample of the fault indicator. As part of the tests, the indicator is subjected to secondary test using the Omicron CMC256plus tester as well as test on fault records that have been converted to COMTRADE for this purpose. The last series of tests carried out uses the physical model of the medium voltage system, where the tested equipment is subjected to fault states in the compensated whit auxiliary resistor system and isolated system. Furthermore, part of the thesis is research of new methods of earth fault detection, including their principles and function description. Also included in the thesis is an overview of manufacturers of indicators, or protection, who are involved in the production of earth fault protection.
Testing of the admitance principle of the fault indicator
Musil, Milan ; Vyčítal, Václav (referee) ; Topolánek, David (advisor)
The thesis deals with the proposal, implementation and evaluation of test for fault condition indicators. Thesis focusing on earth fault indicators based on admittance principles. These indicators must be able to evaluate earth faults in compensated, compensated with auxiliary resistor, unearthed and high-resistance earthed networks. The proposed tests verify the current and voltage measurement errors in inputs including monitored characteristic variables such as conductance and susceptance. The proposed test are applied to a selected ample of the fault indicator. As part of the tests, the indicator is subjected to secondary test using the Omicron CMC256plus tester as well as test on fault records that have been converted to COMTRADE for this purpose. The last series of tests carried out uses the physical model of the medium voltage system, where the tested equipment is subjected to fault states in the compensated whit auxiliary resistor system and isolated system. Furthermore, part of the thesis is research of new methods of earth fault detection, including their principles and function description. Also included in the thesis is an overview of manufacturers of indicators, or protection, who are involved in the production of earth fault protection.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.